CHAPTER 4 SERIAL PORTS
4-1
Figure 4-1 Serial port connector location
CHAPTER SYNOPSIS
SERIAL PORTS CHAPTER 4
Overview of RPC-2350 serial capabilities
Using RS-422/485
Networking with RS-485
Preventing program stops (breaks)
SPI port information
DESCRIPTION
The RPC -2350 has two serial ports that can be used for
interfacing to a printer, terminal, or other ser ial devices.
A SPI port is also pr ovided. This chapter descr ibes their
characteristics and how to use them. Frequent
references are m ade to commands listed in the
CAMBA SIC Programming Manual. Please refer to this
manual for more information.
Serial por ts are num bered C OM 1 and CO M2. COM 1 is
used for program development. It is RS-232 only.
During run time, it can be used for other functions such
as writing to a printer or serial display. COM 2 is a
general purpose serial port. Its outputs can be RS-232,
RS-422, or RS-485 level compatible.
Both ports support XO N/XOF F protocol to contr ol data
transmission. Each por t has a 256 character interrupt
driven input and output buffer. This allows charac ters to
be sent out (using PRINT) without slowing down
program execution. However, if the PRINT buffer fills,
program execution is suspended until the buffer em pties.
Both ports have a 256 character input buffer. When
more than 256 characters have been received, extra ones
are ignored.
The baud rate, parity, data length, stop bits, and com
port type are changed using the CONFIG BAUD
command.
COM1 SERIAL PORT
COM 1 is J1 and is called the Console port on the card.
This port uses a VTC-9F serial cable to connect to a PC
and other external serial devices. The cable is wired
one-to-one, with pin 1 on the 10 pin connector lining up
to pin 1 on the D B-9. T he connector plugs dir ectly into
a 9 pin serial port connector on a PC.
This port is normally used for program ming. D uring
run time it may be used as a general purpose seria l port.
When used for programming or with the INPUT
statement, it will accept ASCII character values from 0
to 127. When used with the INKEY$ and COM$
functions, it returns ASCII values from 0 to 255.
No control lines (like CTS or RTS) are available on
COM 1. A pull up resistor is on the CTS output should a
communication program or device require a positive
indication the port is alive.
COM2 SERIAL PORT
COM 2 is an RS-232, RS-422, or RS-485 por t. It also
uses a VTC-9F serial cable to connect to PC’s and other
serial devices. CO M2 is identical to COM1 except that
it has 2 hardware handshaking lines, CT S and RTS.
NOTE: The CTS output line is low on power up or
reset. This is to prevent the RS-485 transmitter
from turning on and adversely affecting network
communication. RS-232 communication may
be affected by holding off the sender from
sending data. You must enable the CTS output
as described below under “Comm unication flow
control” .
Jumper W4 determines if COM 2 receive is RS-232 or
RS-422/485.
W4[1-2] RS-422/485
W4[2-3] RS-232
Use CONFIG BAUD to tell the system the type and
characteristics of this port. Default is RS-232, 19, 200
baud, 8 data, 1 stop bit. .