OVERVIEW SECTION 1
Page 1-1 RPC-330
DESCRIPTION
The RP C-330 is an embedded contr oller with a built in
Basic language. Several features make it suitable as a
stand alone unit:
! Built in RPBASIC-52 programm ing language
autoruns at power up. On card flash EPROM
programmer can save 8 programs to 62K, or about
500K total.
! High speed multimode counters accept quadrature or
single inputs. Programmable for up/dow n, binary,
divide-by-N, X1, X2 or X4 quadrature counting.
Interrupt on counts.
! LCD character and gr aphic display a nd keypad p orts
for operator interface.
! Two RS-232 serial ports, one of which is
configurable for RS-422/485.
! Watchdog timer resets card if a program "crashes".
! 34 digital I/O lines, 9 of which are high current
outputs. 24 of these lines can connect to an opto
rack or other TTL devices.
! Eight channel, 12 bit resolution analog to digital
converter. Configurable operational amplifiers
allow you to signal condition inputs or measure
temperature.
! 32K, 128K, or 512K RAM battery backable to save
process variables and other data when power is off.
! 32K or 512K flash EPROM to save program s and
data.
The RPC -330 uses an 80C320 CPU operating at 22.1184
Mhz. It can operate stand alone or on a network using
the RS-485 port. Its 5.025" x 6.9" size with 4 mounting
holes makes it easy to mount in a NEMA box.
Compactness is enhanced by on-board analog and digital
terminal strips.
RPBASIC-52 programming language is standard. T his
language is a version of the original Intel BASIC-52. It
was modified for the RPC -330 for control, data
acquisition applications, and on board hardware features.
Program development takes place on your PC, using
your word processor, or on the RPC-330. Programs
from your PC can be downloaded using a serial
communication program.
MANUAL ORGANIZATION
This manual provides all the infor mation r equired to
install, configure, and operate the RPC-330. Using this
manual you will be able to:
Interface the RPC-330 to your IBM compatible PC
or terminal.
Understand the operation of the RPC-330 hardware
using RPBASIC-52 programming software.
This manual assumes you are familiar with some type of
BASIC programming software. The syntax used by
RPBASIC-52 is similar to BASIC-52. If you are not
experienced with any BASIC softwar e, y ou may w ant to
refer to books and training programs available through
your local book store. The BASIC-52 Programm ing
Manual has information and examples for the original
commands. Commands unique or modified by
RPBASIC-52 are in the Software Supplement in this
manual.
The RPC -330 uses a Dallas Semiconductor DS80C320
processor. Additional information can be obtained from
Dallas Semi (214-450-0448, FAX 214-450 0470), or
your distributor.
MANUAL CONVENTIONS
Information appearing on your screen is shown in a
different type.
Example:
RPBASIC-52 V1.0
Copyright Intel (1985) and Remote Processing
Bytes free: 27434