Error Messages - 4
NUM MESSAGE EXPLANATION
27 < Data > 255> The argument or parameter may not exceed 255.
28 < Data > 65,535> The argument or parameter may not exceed 65,535.
29 < Can’t LOAD pr ogram> Program does not exist in EEPROM.
30 < Expected (> CAM BASIC is expecting a left parenthesis or an expression.
31 < Expected )> CAM BASIC is expecting a r ight parenthesis.
32 < Expected ]> CAM BASIC is expecting a r ight brack et.
33 < Need more> Another parameter or argum ent is expected.
34 < Expected – > CAMBASIC is expecting a “– ”.
35 < TO missing> A TO was missing in a FOR/N EXT structure.
36 < Expected GOTO> A GOTO is expected after a conditional.
37 < Expected GOSUB> A GO SUB is expected after a conditional.
38 < Expected THEN> A TH EN is expected afte r a conditional.
39 < Expected = > An “= ” sign is expected.
40 < Expected ;> A semicolon is missing in a PRINT statement with a prom pt string.
41 < Varia ble name length> The variable name is longer than 40 character s.
42 < No Autorun program> CAMBASIC cannot find the autorun program.
43 < Task construction> A mismatch of task numbers or task construction has occurred.
44 < CONF IG mismatch> A CON FIG statement was impr operly constructed.
45 < Com mand no t available> You have used a command w hich is not implemented on your card. F or
example, the AIN is useless on car ds without analog input.
46 < DO loop counter empty> Encountered an END DO w ithout a previous DO /n statem ent.
47 < Time > 327.67 sec> Self explanatory