RESTORE
Syntax: RESTORE
Function: Resets the READ instruction pointer to the beginning of the D ATA list.
Mode: Run
Use: RESTORE
Cards: All
DESCRIPTIO N
After a RESTOR E statement is executed, the next RE AD statement acc esses the first item in th e first data
statement in the program.
ERROR
NO DATA - no DATA list provided.
EXAMPLE
100 READ A,B,C
110 PRINT A,B,C
120 RESTORE
130 READ X,Y,Z
140 PRINT X,Y,Z
150 READ A,B,C
160 PRINT A,B,C
150 DATA 1,2,3*2
150 DATA 6,9,12
>run
1 2 6
1 2 6
6 9 12