Commands - 4
AOT
Process Statement
SYNTAX: AOT channel,value
PURPOSE: To wr ite data to a analog output port.
REMARK S: AOT causes the an alog output voltage to move to a level specified by the value. The voltage will
remain constant until another AOT statement is executed. The analog output ICs change voltage as
fast as the CPU can write to them. See your hardware manual for more information.
RELATED: CONFIG AOT
EXAMPLE: See your hardware manual.
ERROR: < Data negative> for channel and value
< Data out of range> if channel too large
< Command not available> if card does not have hardware support